Shin Nippon Machinery Co LTD established on 1951.
Manufacture and sale of steam turbines and pumps.
Chinese Version |
|
|
The H Series, and high-output high speed HO series based upon it, are SNM's standard small single stage horizontal turbines for general use.
In addition, there is the CC series, also single stage horizontal turbines, designed as high-RPM devices for use with high-speed compressors, and the V series, designed for vertical installation. |
|
Used in oil refineries and chemical plants, sugar refineries, and power plants, and other industrial operations to drive pumps, fans, compressors, mills, shredders, and to generate electric power. |
|
|
? |
Back-pressure single stage steam turbine |
Model |
H-133 |
H-142 |
H-163 |
H-183 |
Maximum output (kW) |
300 |
600 |
1,000 |
1,500 |
Maximum inlet steam pressure (kgf/cm2g) |
45 |
45 |
45 |
45 |
Maximum inlet steam temperature (°C) |
450 |
450 |
450 |
450 |
Maximum exhaust pressure (from vacuum to maximum) (kgf/cm2g) |
7 |
7 |
7 |
7 |
|
|
? |
Back-pressure single stage steam turbine |
Model |
HO142 |
HO163 |
HO183 |
Maximum output (kW) |
600 |
1,500 |
2,500 |
Maximum inlet steam pressure (kgf/cm2g) |
60 |
60 |
60 |
Maximum inlet steam temperature (°C) |
500 |
500 |
500 |
Maximum exhaust pressure (from vacuum to maximum) (kgf/cm2g) |
15 |
24 |
11 |
|
|
Model |
CC-400 |
CC-401 |
CC-600 |
CC-601 |
CC-800 |
CC-802 |
Maximum output (kW) |
2,000 |
1,500 |
3,000 |
2,000 |
3,000 |
3,000 |
Maximum inlet steam pressure (kgf/cm2g) |
67 |
67 |
67 |
67 |
67 |
67 |
Maximum inlet steam temperature (°C) |
500 |
500 |
500 |
500 |
500 |
500 |
Maximum exhaust pressure (from vacuum to maximum) (kgf/cm2g) |
15 |
15 |
15 |
15 |
12 |
12 |
|
|
? |
Back-pressure single stage steam turbine |
Model |
V-136 |
V-145 |
Maximum output (kW) |
300 |
500 |
Maximum inlet steam pressure (kgf/cm2g) |
45 |
45 |
Maximum inlet steam temperature (°C) |
450 |
450 |
Maximum exhaust pressure (from vacuum to maximum) (kgf/cm2g) |
7 |
7 |
|
|